Deye SUN-40K-SG01HP3-EU-BM4 High Voltage Hybrid Inverter

  • Power: 50kW, 40kW, 30kW
  • Temperature Range: -45~60℃
  • Voltage Range: 160~800V
  • Size: 527*894*294MM
  • Weight: 75KG
  • Warranty: 5 Years

Product Detail

Product Tags

场景图 40k参数特点图

Model
SUN-30K-SG01HP3-EU-BM3
SUN-40K-SG01HP3-EU-BM4
SUN-50K-SG01HP3-EU-BM4
Battery Input Data
Battery Type
Lithium-ion
Battery Voltage Range(V)
160~800
Max. Charging Current (A)
50+50
Max. Discharging Current (A)
50+50
Number of battery input
2
Charging Strategy for Li-Ion Battery
Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W)
39000
52000
65000
Max. DC Input Voltage (V)
1000
Start-up Voltage (V)
180
MPPT Range (V)
150-850
Full Load DC Voltage Range (V)
360-850
360-850
450-850
Rated DC Input Voltage (V)
600
PV Input Current (A)
36+36+36
36+36+36
36+36+36+36
Max. PV ISC (A)
55+55+55
50+50+50
50+50+50+50
Number of MPPT / Strings per MPPT
 3/2
4/2
4/2
AC Output Data
Rated AC Output and UPS Power (W)
30000
40000
50000
Max. AC Output Power (W)
33000
44000
55000
AC Output Rated Current (A)
45.5/43.5
60.7/58
75.8/72.5
Max. AC Output Rated Current (A)
50/47.8
66.7/63.8
83.4/79.7
Max. Three-phase Unbalanced Output Current
60
70
83.3
Max. Continuous AC Passthrough (A)
200
Peak Power (off grid)
1.5 time of rated power, 10 S
Generator input/Smart load
/AC couple current (A)
45.5 / 200 / 45.5
60.7 / 200 / 60.7
75.8 / 200 / 75.8
Power Factor
0.8 leading to 0.8 lagging
Output Frequency and Voltage
50/60Hz; 3L/N/PE 220/380, 230/400Vac
Grid Type
Three Phase
Total Harmonic Distortion (THD)
<3% (of nominal power)
DC current injection
<0.5% In
Efficiency
Max. Efficiency
97.60%
Euro Efficiency
97.00%
MPPT Efficiency
99.90%
Protection
Integrated
PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection,Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection,Output Shorted Protection, Surge protection
Output Over Voltage Protection
DC Type II/AC Type III
Certififications and Standards
Grid Regulation
VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150
Safety EMC / Standard
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range (℃)
-45~60℃, >45℃ derating
Cooling
Smart cooling
Noise (dB)
≤65 dB
Communication with BMS
RS485; CAN
Weight (kg)
75
Size (mm)
527W×894H×294D
Protection Degree
IP65
Installation Style
Wall-mounted
Warranty
5 years

导购67.我们的德国公司公司文字介绍部分我们的展会


  • Previous:
  • Next:

  • Write your message here and send it to us